ORION®
Automated Meter Reading System for Trimble® Ranger 3
Installation & Operation Manual
ORI-IOM-64-EN (February 2013)
62014-154 Rev. 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 123 124

Shrnutí obsahu

Strany 1 - ORI-IOM-64-EN (February 2013)

ORION®Automated Meter Reading System for Trimble® Ranger 3Installation & Operation ManualORI-IOM-64-EN (February 2013)62014-154 Rev. 2

Strany 2 - Page ii February 2013

5. Tap ORION Field Application to start the software. Result: The Clock Verication screen opens as shown in Figure 5. Figure 4: ORION Field Ap

Strany 3 - CONTENTS

Working with BluetoothThe handheld has been designed to operate with the internal Bluetooth®—a short-range wireless communication technology that exch

Strany 4 - Page iv February 2013

Power:• Tap if you want to select "Maintain Bluetooth connections when device is turned off."• Tap if you want to select "Allow Bluet

Strany 5 - INTRODUCTION

Working with GPSTap Windows Start> Settings> System> System Information. Then select Wireless from the selections that display across the top

Strany 6 - License Requirements

Working with the Speaker/MicrophoneThe handheld comes with an integrated speaker and a microphone. It also has a 3.5 mm audio jack that is wired for a

Strany 7 - PART I: USER GUIDE

Factory Reset/Clean BootThis procedure resets the Trimble Ranger to "factory fresh" condition and removes all previously added software, inc

Strany 8 - SOFTWARE SECURITY MODES

USING THE HANDHELD KEYPADTrimble Ranger 3 handheld keypadYellow label denotes Hot KeyOn/O power Windows® StartFn (Function) key + Yellow label key =

Strany 9 - PROGRAM STARTUP

HOT KEYS, QUICK KEYS, READ KEYSThe handheld software includes a number of Hot Keys and Quick Keys that provide meter reading shortcuts.Hot Key Press

Strany 10

CONFIGURATION OPTIONSThe Trimble Ranger 3 handheld is available in three configuration options: • Handheld with an internal ORION ME transceiver and

Strany 11 - Onscreen Keyboard

Connecting an External Mobile Transceiver or ReceiverFor handhelds configured with an internal transceiver or receiver (Config 1 and Config 2 on previ

Strany 12 - COPYRIGHT SCREEN

APPENDIXInstallation & Operation ManualPage 109 February 2013

Strany 13 - MAIN MENU

NOT: N The first time the software is accessed, the License Agreement screen opens automatically, after the Clock Verification screen. Read the sof

Strany 14 - READING A ROUTE

GLOSSARYTERM DESCRIPTIONADE The Absolute Digital Encoder (ADE) is a position-based encoder that senses the position of each number wheel to determine

Strany 15 - Account Read Screen

TERM DESCRIPTIONORION ME, ORION SE The ORION ME (Migratable Endpoint) and ORION SE (Smart Endpoint) are two-way utility management solutions. ORION ME

Strany 16 - Page 16 February 2013

STATUS CODESStatus codes are displayed on several of the screens within the software. The following is a list of status codes and their descriptions.S

Strany 17 - Page 17 February 2013

GAS METER DRIVE ROTATIONThe table below displays the drive gear rotation direction for common gas meter makes/models.CW = clockwiseCCW = counter clock

Strany 18 - Page 18 February 2013

HANDHELD STATUS INDICATORSStatus indicators may display at the top of the screen. The status indicator icons are shown here with a description of what

Strany 19 - Capturing Meter Readings

ROUTE MEMORY STICKInitializing the Memory Stick The memory stick must be initially matched to the handheld before a route can be loaded.NOT:N If you n

Strany 20 - Page 20 February 2013

LOADING A ROUTE1. Start at the Copyright screen. If you need help, refer to "Copyright Screen" onpage12.2. Insert the memory stick with

Strany 21 - ORION ME Details

UNLOADING A ROUTE1. Start at the Copyright screen. If you need help, refer to "Copyright Screen" onpage12.2. Insert the memory stick int

Strany 22 - Page 22 February 2013

USING VERSAPROBE WITH BLUETOOTH IMPORTANTThe VersaProbe should physically be within 10 feet of the handheld to set up a successful wireless connection

Strany 23 - Historical Data

Set the VersaProbe COM Port on the Handheld1. Access the Main Menu in the ORION Field Application software on the handheld. If you need help, go to &

Strany 24

COPYRIGHT SCREENThe Copyright screen displays the following information.• Program name, software version and copyright information• Device name (han

Strany 25 - Page 25 February 2013

TROUBLESHOOTINGCommunications Error The correct COM port must be set for any hardware attached to the handheld. Refer to "Hardware" onpage

Strany 26 - Page 26 February 2013

Recovering a Backup Route Unload FileOnce a route file is unloaded, a backup route file can only be accessed using a security code and the following s

Strany 27 - READ MENU

TECHNICAL SUPPORTErrors do not normally occur, so it is important to report all occurrences of error windows to Badger Meter Technical Support. NOT:

Strany 28 - Page 28 February 2013

INTENTIONAL BLANK PAGE Installation & Operation ManualPage 123 February 2013

Strany 29 - Page 29 February 2013

www.badgermeter.comADE, ORION, ReadCenter and RTR are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the

Strany 30 - View High/Low

MAIN MENUThe Main Menu is the starting point for all meter reading operations. There are four options on the Main Menu. Figure 12: Main MenuRead Rout

Strany 31 - appears in the

READING A ROUTERead Route Login1. Tap Read Route on the Main Menu. Result: The Pin/User ID Entry login screen displays.2. Enter a three to ve char

Strany 32 - Page 32 February 2013

Account Read ScreenThe account read screen is the main reading screen on the handheld. The information available on the screen is shown in Figures 15,

Strany 33 - Page 33 February 2013

Figure 16: Account read screen- meter informationMeter InformationReading display field The meter reading displays in this field. In manual and touch

Strany 34 - Page 34 February 2013

Figure 17: Account read screen - status and navigationStatus and NavigationReading mode The selected reading mode is displayed on the upper left side

Strany 35 - Erase Read

Changing Read ModeChoose Manual or Auto mode when reading routes with the handheld to advance to the next account manually or automatically.Manual Mod

Strany 36 - UTILITIES

Capturing Meter ReadingsThe ORION Field Application software captures meter readings in one of three ways:• ORION RF read• VersaProbe touch pad read

Strany 37 - Settings

ORION® Automated Meter Reading System for Trimble® Ranger 3Page ii February 2013

Strany 38 - Page 38 February 2013

Manual and Touch Pad ReadsThe handheld can read ORION endpoints and touch pads, and collect manual reads. If the route contains a mix of meters, the h

Strany 39 - Page 39 February 2013

ORION ME DetailsThe account read screen for an ORION ME endpoint provides access to the two-way communication functionality of the ORION ME endpoint.

Strany 40 - Page 40 February 2013

Figure 25: Work item not assigned Figure 26: Work item assignedIf work items are NOT set to be performed automatically in ReadCenter Analytics or An

Strany 41 - Page 41 February 2013

Historical DataWhether initiated automatically or manually, the ORION field application software is capable of extracting historical profile data from

Strany 42 - Customizations

Figure 28: Select Cubic Feet, Gallons or Cubic MetersFigure 29: Select registration and reading resolution4. Tap Select.Result: The data is request

Strany 43 - ROUTE INFO

Requesting Extended Status ManuallyExtended status includes additional information which has been programmed into an endpoint, including meter type an

Strany 44 - PROGRAM & QUICK READ

Requesting Firmware ManuallyIf a work item was not assigned by the reading data management operator, you can manually initiate a request for the firmw

Strany 45 - VersaProbe

READ MENUTo access the Read Menu, tap the Menu button on the account read screen. The Read Menu has several functions which are associated with the ac

Strany 46 - ORION ENDPOINT UTILITY

SearchThere are multiple ways to search for a meter record in the route. To find a meter using the account information, use the Search Fields function

Strany 47 - ORION ME ENDPOINT UTILITY

More Search Options Bookmarked Accounts Bookmarking make accounts easier to find later. To bookmark an account, press the B key twice (BB) or press Fn

Strany 48 - ORION ME IR Programming

CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5PART I: USER G

Strany 49 - Page 49 February 2013

Manual ReadManual Read allows entering a meter reading for the account which was viewed prior to choosing the Read Menu option.1. From the customer a

Strany 50 - Page 50 February 2013

Read DirectionThe Read Direction option allows the meter reader to walk the route in reverse of the order it was loaded into the handheld. 1. Tap Rea

Strany 51 - Page 51 February 2013

Reader CodesReader Codes are predefined by the reading data management software operator. The codes are often used to describe typical, non-emergency

Strany 52 - Page 52 February 2013

Text MessagesText Messages can be created when appropriate Trouble or Reader Codes are not available. Text messages are alphanumeric, with up to 140 c

Strany 53 - ORION ME Extended Status

Edit a Message1. From an account screen with a text message, tap Menu > Comments > Text Messages or press Fn+N on the keypad from an account sc

Strany 54 - Page 54 February 2013

Erase ReadNOT: N If a reading is not stored in the customer record, the Erase Read option does not display on the Read Menu.1. Tap Erase Read on the

Strany 55 - Page 55 February 2013

UTILITIES The Utilities Menu can be accessed either from the ORION Field Application Main Menu or from Read Menu> Utilities. The Utilities Menu has

Strany 56 - Page 56 February 2013

Battery Info The second option on the Utilities Menu is Battery Info. 1. Tap Battery Info to display information about the battery charge and life. 2

Strany 57 - Page 57 February 2013

HardwareThe Hardware Settings screen displays the communication (COM) ports for the hardware attached to the handheld. The COM ports will be set durin

Strany 58 - Page 58 February 2013

Program Options1. Tap Program Options on the Settings Menu to display the rst of three Program Options screens. 2. On the Options 1 of 3 screen, ta

Strany 59 - Page 59 February 2013

ORION SE / ME Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69Programming an ORION ME Ga

Strany 60 - Figure 99: GPS manual entry

High/Low OptionsTap High/Low Options on the Settings Menu to display the settings for high or low readings. Advance on High/Low: A high reading (highe

Strany 61 - Page 61 February 2013

Displayable Field Settings Tap Displayable Field Settings on the Settings Menu to see the User Defined Fields screen. This screen displays the predef

Strany 62 - ORION ME RF Quick Read-All

Customizations Tap Customizations on the Settings Menu to access the three customization screens. The meter reader has complete control of these three

Strany 63 - Page 63 February 2013

ROUTE INFOFigure 74: Route summary informationThe Route Transfer Info screen can be accessed from the Main Menu. The screen provides date and time st

Strany 64 - ORION ME RF Quick Read-Single

PROGRAM & QUICK READProgram & Quick Read is used to perform a number of functions on ORION endpoints and touch modules. The most common uses o

Strany 65 - Page 65 February 2013

VersaProbeA VersaProbe wand is used for close proximity touch pad meter reading. The wand can be connected to the handheld serial port or via a wirele

Strany 66 - ORION ME Proling

ORION ENDPOINT UTILITYThe ORION Endpoint Utility is used to program and quick read ORION ME and ORION CE endpoints, and to increase the test sampling

Strany 67 - Page 67 February 2013

ORION ME ENDPOINT UTILITYThe ORION ME endpoint utility functions are used for IR programming and IR/RF historical interval data extraction. This selec

Strany 68 - Page 68 February 2013

ORION ME IR ProgrammingThe ORION ME IR Programming option is used to read and program ORION ME or SE water and gas endpoints using the IR programming

Strany 69 - ORION SE / ME Installation

Performing an IR Quick Read1. Connect the IR cable to the nine-pin serial port on the bottom of the handheld. 2. Align the optical read head of the

Strany 70 - Page 70 February 2013

INTRODUCTIONThe ORION® Automated Meter Reading System for the Trimble® Ranger 3 Installation and Operation Manual is arranged as follows:• Part I: Us

Strany 71 - Page 71 February 2013

NOT: N An ORION ME or SE endpoint connected to an ADE (or approved competitive three-wire encoder) does not require programming to clear a tamper. Af

Strany 72

1. Double-tap the reading in the box to the right of the Reading eld. Result: The current reading in the eld is highlighted.Figure 86: RTR Reading

Strany 73 - ORION CE ENDPOINT UTILITY

Force Read (ADE, HR-E LCD)When an ORION ME or SE (in mobile mode) endpoint is connected to an ADE or HR-E LCD encoder, the Force Read button displays

Strany 74 - ORION CE IR Programming

ORION ME Extended StatusExtended status provides additional information which has been programmed into an endpoint. NOT:N Extended status information

Strany 75 - Performing an IR Quick Read

RTR Extended StatusFigure 90: Extended Status- RTRThe status indicators described below apply for an ORION ME or SE (mobile mode) endpoint when conne

Strany 76 - Page 76 February 2013

ADE Extended StatusFigure 91: Extended Status - ADEThe status indicators described below apply for an ORION ME or SE (mobile mode) endpoint when conn

Strany 77 - Page 77 February 2013

High Resolution (HR) E LCD Extended StatusFigure 92: Extended Status - HR-E LCDThe status indicators described below apply for an ORION ME or SE (mob

Strany 78 - ORION CE RF Quick Read - All

High Resolution (HR) E-Series Extended StatusFigure 93: Extended Status - HR E-SeriesThe status indicators described below apply for an ORION ME or S

Strany 79 - Page 79 February 2013

Programming Meter Type, Size and Units of Measure (RTR)To program the meter type and size for an RTR encoder, follow these steps.1. Tap the Meter Siz

Strany 80 - ORION CE RF Quick Read-Single

Advanced IR ProgrammingAfter reading an ORION ME endpoint, tap the Advanced button on the ORION ME IR Programming screen to access more information an

Strany 81 - Page 81 February 2013

Handheld CongurationThe handheld can be ordered with the following configurations to meet the needs of the utility. • Internal ORION ME transceiver

Strany 82 - Page 82 February 2013

Manually Setting the GPS Location1. Tap the Set GPS Location button on the Advanced screen. 2. Use the handheld keypad or the onscreen keyboard to 

Strany 83 - Page 83 February 2013

Starting a Flow Rate Study for ME/SE Endpoints A flow rate study is a week-long study that can be performed on an ME or SE (in mobile mode) endpoint t

Strany 84 - Page 84 February 2013

ORION ME RF Quick Read-AllThe ORION ME RF Quick Read-All screen displays readings for all ORION ME endpoints in range, up to 50 readings. One endpoint

Strany 85 - ESERIES

Single Reading View1. Tap the Single button on the ORION ME RF Quick Read-All screen to toggle between the list view of all the endpoints and an indi

Strany 86 - Changing a COM Port Setting

ORION ME RF Quick Read-SingleThe ORION ME RF Quick Read - Single screen is used to perform a quick read on a single ORION ME endpoint serial number us

Strany 87 - PART II: HANDHELD OPERATION

3. Tap Advanced to access more information and additional commands. 4. Tap Back to return to the RF Quick Read-Single screen.5. Tap Stop to end the

Strany 88 - System Components

ORION ME ProlingORION ME Profiling is used to extract IR or RF historical interval data from an ME or SE (in mobile mode) endpoint for viewing in the

Strany 89 - General Care of the Handheld

RF ExtractionTo access profile data for an ORION ME or SE (in mobile mode) endpoint using RF, follow these steps.1. Tap the IR/RF box so RF displays.

Strany 90 - Initial Setup

ME Profiling Fields and ButtonsOldest Reading The date and time of the oldest reading in the data extracted.Interval The reading interval at which the

Strany 91 - Page 91 February 2013

ORION SE / ME Installation The ORION SE/ME Installation screens are used for endpoint installation which includes setting the GPS, setting the meter t

Strany 92 - Page 92 February 2013

PART I: USER GUIDEInstallation & Operation ManualPage 7 February 2013

Strany 93 - SD and SIM Cards

Check the "Listen for Gateway" box on the Step 2 screen for fixed network applications.Align the optical head of the IR cable with the endpo

Strany 94 - Handheld Basic Operations

Programming an ORION ME Gas EndpointNOT: N Before beginning, make sure the IR programming cable is connected and the IR COM port is set correctly. Re

Strany 95 - Page 95 February 2013

NOT: N For a list of meters and the rotation direction of the drive gear, refer to "Gas Meter Drive Rotation" onpage113 in the Appendix.F

Strany 96 - Page 96 February 2013

ORION CE ENDPOINT UTILITYThe ORION CE endpoint utility is used to program and quick read ORION CE endpoints. To access the software, tap ORION CE on t

Strany 97 - Page 97 February 2013

ORION CE IR ProgrammingThe ORION CE IR Programming screen is used to start, stop and pause ORION CE endpoints as well as program an ORION CE endpoint

Strany 98 - Page 98 February 2013

Performing an IR Quick ReadNOT: N An IR read must be performed before any other function can be used. 1. Connect the IR cable to the nine-pin serial

Strany 99 - Page 99 February 2013

Programming an ORION CE Endpoint1. Double-tap the reading in the Reading eld box as shown in Figure 134. Result: The current reading in the eld is

Strany 100 - Working with Bluetooth

Force Read (ADE)With an ADE encoder, the Force Read button displays instead of the Program button. Force Read is used to view the real-time encoder o

Strany 101 - Page 101 February 2013

ORION CE RF Quick Read - AllThe ORION CE RF Quick Read -All screen displays readings for all ORION CE endpoints in range, up to 50 readings. One endpo

Strany 102 - Working with GPS

Single Reading View1. Tap the Single button on the ORION CE RF Quick Read - All screen to toggle between the list view of all the endpoints and the i

Strany 103 - Page 103 February 2013

SOFTWARE SECURITY MODES The Trimble Ranger 3 handheld can operate in one of two modes:• Admin mode gives full-use access to all the software loaded o

Strany 104 - Factory Reset/Clean Boot

ORION CE RF Quick Read-SingleThe ORION CE RF Quick Read - Single screen is used to perform a quick read on a single ORION ME endpoint serial number us

Strany 105 - USING THE HANDHELD KEYPAD

Programming an ORION CE Gas EndpointNOT: N Before beginning, make sure the IR programming cable is connected and the IR COM port is set correctly. Re

Strany 106

4. Locate the drive circle for the gas endpoint. • Use the selections in the top half of the screen to filter the list on the bottom by choosing Int

Strany 107 - CONFIGURATION OPTIONS

Reprogramming the Gas Drive Circle To reprogram an ORION CE endpoint and change the gas drive circle after it has been programmed, follow these steps.

Strany 108 - Handheld with

Result: The Gas Drive Circle screen is displayed again. 5. Select the drive circle settings, then tap the Select button. Figure 152: Select new gas

Strany 109 - APPENDIX

ESERIES The E-Series utility allows communication between the handheld and the E-Series meter via the IR port. This option is used to increase the te

Strany 110 - GLOSSARY

SETTINGS FOR PROGRAM & QUICK READWhen using Program & Quick Read or the ORION endpoint utility, it is important to make sure the COM (communic

Strany 111 - Page 111 February 2013

PART II: HANDHELD OPERATIONInstallation & Operation ManualPage 87 February 2013

Strany 112 - VALID COM PORTS

TRIMBLE RANGER 3 HANDHELD OVERVIEWThe Trimble Ranger 3 is a handheld computer designed for fully automated data collection along a route for meters eq

Strany 113 - GAS METER DRIVE ROTATION

Handheld Top ViewHandheld Bottom ViewGeneral Care of the HandheldUse a mild detergent and a clean soft cloth to clean the body of the handheld. Do not

Strany 114 - Status Indicators

PROGRAM STARTUPNOT:N Before using the handheld for the first time, refer to "Initial Setup" onpage90 in Part II to ensure that the device

Strany 115 - ROUTE MEMORY STICK

Initial Setup1. Install the battery.The Lithium-Ion (Li-Ion) battery is shipped detached from the unit. Insert the battery at the bottom of the compa

Strany 116 - LOADING A ROUTE

NOT: N For more information on the battery, refer to "Working with the Handheld Battery" onpage92.FULLY CHARGE THE BATTERY AT LEAST 4 HOU

Strany 117 - UNLOADING A ROUTE

Working with the Handheld BatteryCharging the BatteryThe AC charger that ships with the unit has adapters to fit almost every electrical outlet. Conne

Strany 118 - Page 118 February 2013

Conserving the BatteryThe handheld conserves battery power by turning itself off when not in use. Press and release the green power key on the keypad

Strany 119 - Page 119 February 2013

Handheld Basic OperationsTurning the Handheld OnTo turn on the handheld, press the green power key on the keypad. An audible beep sounds and the “boot

Strany 120 - TROUBLESHOOTING

Using the Touch ScreenNOT: N This manual provides instructions for touch screen navigation and operation of the handheld. Quick Keys and Hot Keys are

Strany 121 - Route Unload Error

Changing the Handheld Date and TimeTHE DATE AND TIME ON THE TRIMBLE RANGER 3 HANDHELD MUST BE ACCURATE TO ENSURE COMMUNICATION WITH THE ORION ENDPOINT

Strany 122 - TECHNICAL SUPPORT

Barcode ScannerDepending on the configuration, the handheld may include an integrated laser ID barcode scanner. NOT:N To be able to use the barcode sc

Strany 123 - INTENTIONAL BLANK PAGE

4. Tap to select the Circle Shortcut button. You may need to scroll to nd it. 5. Tap in the Assign a program eld and select Scan Agent. You may ne

Strany 124

FlashlightDepending on the configuration, the handheld may include a camera. The dual LEDs for the camera flash can also be used as a flashlight.Tap W