Force Read (ADE)
With an ADE encoder, the Force Read button displays instead of the Program button. Force Read is used to view the
real-time encoder odometer value.
1. Align the optical read head of the IR cable with the
ORION CE endpoint IR port.
2. Tap Force Read.
Result: The endpoint transmission starts and the
reading value updates to reect the current encoder
odometer value.
Figure 137: Force Read on ADE
Listen
The Listen button activates the radio frequency to listen for a reading from the endpoint. Tap the Listen button to display the
RF quick read information for the selected endpoint.
For additional information, refer to "ORION CE RF Quick Read-Single" onpage80.